Buying the wrong size is the most common mistake with air purifiers and air conditioners. A purifier that is too small barely moves the air in a big room. An AC that is too small runs all day and never cools the room. This free calculator sizes both for your room in a few seconds: enter the room length, width and ceiling height, then pick a tab.

Estimates for planning only. Real needs change with insulation, windows, climate and how the unit is placed.

How the Air Purifier Size Calculator Works

An air purifier’s power is shown as its CADR (Clean Air Delivery Rate), the cubic feet of filtered air it delivers per minute. AHAM, the group that runs the CADR test, rates purifiers for smoke, dust and pollen. Smoke has the smallest particles, so the smoke CADR is the best number to compare.

The calculator uses this formula:

Needed CADR = room length × width × ceiling height × air changes per hour ÷ 60

“Air changes per hour” (ACH) is how many times the purifier cleans all the air in the room each hour. AHAM’s well-known 2/3 rule (smoke CADR at least two-thirds of the room’s square feet) works out to 5 air changes per hour in a room with 8 ft ceilings. The CDC also uses 5 air changes per hour as its target for cleaner indoor air. For allergies, pets or smoke, many people choose more headroom, so the calculator offers 6 ACH as well.

Air purifier size chart (8 ft ceilings)

Room size Smoke CADR for 5 ACH Smoke CADR for 6 ACH
150 sq ft 100 CFM 120 CFM
250 sq ft 167 CFM 200 CFM
350 sq ft 233 CFM 280 CFM
500 sq ft 333 CFM 400 CFM
750 sq ft 500 CFM 600 CFM
1,000 sq ft 667 CFM 800 CFM

Higher ceilings mean more air to clean, so a 10 ft ceiling needs 25% more CADR than the chart shows. Brand “room size” claims are often based on fewer air changes per hour, so check the CADR yourself instead of trusting the box.

How the BTU Calculator Works

Air conditioners are rated in BTU (British Thermal Units) per hour, the amount of heat they remove. The calculator starts from the ENERGY STAR room size chart and applies its standard adjustments:

  • Sun: reduce by 10% for a heavily shaded room, add 10% for a very sunny one.
  • People: add 600 BTU for each person above two who regularly uses the room.
  • Kitchen: add 4,000 BTU because cooking adds a lot of heat.
  • Ceilings over 8 ft: the calculator scales the result up for the extra air volume.

BTU chart by room size (ENERGY STAR)

Room size Cooling capacity
100 to 150 sq ft 5,000 BTU
150 to 250 sq ft 6,000 BTU
250 to 300 sq ft 7,000 BTU
300 to 350 sq ft 8,000 BTU
350 to 400 sq ft 9,000 BTU
400 to 450 sq ft 10,000 BTU
450 to 550 sq ft 12,000 BTU
550 to 700 sq ft 14,000 BTU
700 to 1,000 sq ft 18,000 BTU
1,000 to 1,200 sq ft 21,000 BTU
1,200 to 1,400 sq ft 23,000 BTU
1,400 to 1,500 sq ft 24,000 BTU

Portable air conditioners: read the SACC rating

Portable ACs often list two numbers. The larger ASHRAE number is measured in lab conditions. The SACC (Seasonally Adjusted Cooling Capacity) number from the U.S. Department of Energy counts the heat that leaks back in through the hose and case, so it is closer to what you actually get. A “14,000 BTU” portable unit may have an SACC of 9,000 to 10,000 BTU. Match the SACC number to the calculator result. Dual-hose models lose less cooling than single-hose models.

Frequently Asked Questions

What size air purifier do I need for my room?

Multiply your room’s square feet by its ceiling height to get the volume, multiply by 5 air changes per hour, then divide by 60. For a 12 × 14 ft bedroom with 8 ft ceilings that is about 112 CFM, so a purifier with a smoke CADR of 112 or more is a good fit.

What is a good CADR for an air purifier?

A good CADR is one that matches your room. As a quick rule, the smoke CADR should be at least two-thirds of the room’s square feet. A 300 sq ft room needs a smoke CADR of about 200.

How many air changes per hour should an air purifier give?

About 5 air changes per hour is the common target for everyday use. People with allergies, asthma, pets or smoke in the home often aim for 6 or more.

How many BTU do I need for a 400 sq ft room?

The ENERGY STAR chart suggests 9,000 BTU for 350 to 400 sq ft. Add 10% for a very sunny room, and 600 BTU for each extra person beyond two.

Is a bigger air conditioner always better?

No. An oversized AC cools the room too quickly and shuts off before it removes humidity, so the room can feel cold and damp. Pick the size the chart suggests instead of the biggest unit.

Sources

  • AHAM (Association of Home Appliance Manufacturers): CADR ratings and the 2/3 room size rule.
  • U.S. EPA: guide to air cleaners in the home.
  • CDC: ventilation guidance with a target of 5 air changes per hour of clean air.
  • ENERGY STAR: room air conditioner sizing chart and adjustments.
  • U.S. Department of Energy: SACC test procedure for portable air conditioners.